Trap-Receiver 2×2 Digital
Trap-Receiver 2×2 Digital
WT57656
Unfortunately, this article is no longer available.
The Trap-Receiver triggers an alarm when events occur in the network.
2.235,00 kr. (ex. VAT)
Out of stock
The Trap-Receiver triggers an alarm when events occur in the network. Monitoring of devices and status conditions using this device is done via SNMP and SYSLOG. Up to 12 reports can be used to define responses to events from the network. Switch an output or send a response over the network, e.g. via email, TCP or SNMP trap. In addition, the Trap-Receiver offers an SNTP service through which any network stations can obtain the current time.
One box for any application:
- Small System The integrated Web server can be used to configure the Trap-Receiver directly from the browser. It is also possible to monitor the selected events and acknowledge pending messages using the Web interface. Other functions, such as reporting via email, allow out-of-the-box implementation of autonomous applications.
- Big System Standard protocols and interfaces such as OPC, SNMP and SYSLOG enable trouble-free integration into existing systems (e.g. monitoring via SNMP with Nagios). The digital outputs can be used to report events (faults, limit violations) even to already existing automation devices having digital inputs.
![]() |
![]() |
![]() |
|
Monitor the status of the configured reports directly from the browser. Acknowledgements can be carried out directly from the Web interface. The display is self-refreshing and therefore always current.
|
![]() |
|
Additional overview of the status of the in- and outputs, as well as the configured reports. |
Product properties:
Interfaces:
- Network connection
- 10/100BaseT autosensing, RJ45
- 2 digital outputs in 6V-30V industry standard for local alarm issuing
- Externally powered: max. 500mA per output
- Alternatively FET current sourcing, max. 150mA total
- Short-circuit-protected by virtue of thermal safety fuse
- Configurable self-holding
- 2 digital inputs in industry standard usable as acknowledgment input
- Type 1, current sinking in accordance with IEC 1131-2
- Protected against polarity reversal
- Galvanic isolation between the ports
- Isolation voltage 1kV
Management and connectivity:
- Web-based management
- Configuration of the system parameters
- Self-refreshing view of the actions, input and output states
- Acknowledge pending alarms from the browser
- Define activation conditions for max. 12 actions
- 12 freely configurable actions
- Trigger when configured events occur
- Monitor up to 1000 network events
- Report options: email, SNMPv1 trap, UDP and TCP client, syslog messages, FTP
- Optional acknowledgement via digital input or from the Web interface
- SNTP time server
- Current time information is passed using SNTP (Simple Network Time Protocol)
- Service provider for any requesting network station
- Online Web interface language selection
- Deutsch
- English
Power supply:
- PoE (Power over Ethernet)
- Phantom power using data pairs
- Power provided by unused wire pairs (spare-pair power)
- Using external power supply
- Supply from external power supply possible as an alternative to PoE
Standards & more
- Conforms to standards both in office and industrial environments:
- High noise resistance per EN 61000-6-2
- Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
- 5 year guarantee
Technical data:
Connections and displays:
- Network:
- 10/100BaseT autosensing, RJ45
- IPv6 on request
- Adapters:
- 2x screw terminal for power (alternative to POE)
- 6-point screw terminal for IOs
- Digital outputs:
- Short-circuit protected, configurable:
- 2 x Digital Out 6V-30V, 500mA or current sourcing 150mA total
- Digital inputs:
- 2 x Digital In
- max. input voltage +/-30V
- protected against reverse connection within this range
- Switching threshold 8V +/- 1V
- "On" current = 2.2 mA
- Actions:
- 12 actions for local and/or remote messaging
- Response times:
- Data and switching traffic: typically 12 ms
- Galvanic isolation:
- Digital-IO’s - network: min. 1kV
- Power supply:
- Power-over-Ethernet (PoE) or via screw terminal with
- DC 18V-48V (+/-10%) and AC 18Veff-30Veff (+/-10%)
- Current consumption:
- approx. 100mA@24V
- Displays:
- 1 LED for network connection status
- 1 LED for current IO status
- 1 LED for device status
Housing and other data:
- Enclosure:
- Plastic housing for DIN rail mount
- 105 x 75 x 22mm (L x W x H)
- Enclosure rating:
- IP20
- Weight:
- approx. 140g
- Ambient temperature:
- Storage: -25..+70°C
- Operation: 0..+60°C
- Scope of delivery:
- Trap-Receiver 2x2 Digital PoE incl. action management software
- Quick Guide
- W&T product CD
Example applications
Small System
The integrated Web server can be used to configure the Trap-Receiver directly from the browser. It is also possible to monitor the selected events and acknowledge pending messages using the Web interface. Other functions, such as reporting via email, allow out-of-the-box implementation of autonomous applications.
Big System
Standard protocols and interfaces such as OPC, SNMPv1 and SYSLOG enable trouble-free integration into existing systems. The digital output can be used to report events (faults, limit violations) to already existing automation devices having digital inputs.
Application possibilities
Receive SNMPPv1 traps and syslog messages, switch on-site, inform over the network:
The Trap-Receiver receives alarms and messages from the network via SNMPv1 and SYSLOG. 12 actions can be defined for responding to messages or alarms from the network. In addition, changes on the input terminals and even self-definable buttons can be selected as an In-Event, for example to clear an alarm, set an output or send messages. Switch an output (also with self-holding) or send a message over the network, e.g. via e-mail, TCP or SNMPv1 trap. The Trap-Receiver also offers an SNTP service which can be used to obtain the current time information for any network station.
Trap-Receiver as external software watchdog enables safety applications:
In safety-critical applications the Trap-Receiver can also be set up as an external watchdog. Send an SNMPv1 trap to the Trap-Receiver every minute for example using your PC program or network device to turn on the local output. This output remains continuously active during triggering. Only if the trap is not present for 3 minutes, for example, is the output turned off. By implementing a feedback to a device input you can also send an alarm using the above mentioned network services.
The actions and status of the terminals can be monitored directly from the browser.
Perform acknowledgements via mouse click directly in the Web interface.
2 local digital inputs available (e.g. emergency stop buttons, switches).
2 local digital outputs available (e.g. horn, indicator lamp).
Status representation is self-refreshing and therefore always up-to-date.
| Product Title: | Product SKU | Add to Cart |
|---|
Unfortunately, this article is no longer available.