Configuration of the Box-2-Box Master

  • To change the configuration of the Web-IO you first need to obtain the necessary access rights by entering the administrator password.
Login on Web-IO
  • TCP protocol handles communication on the network. The B2B master takes over the function of the client and must be set accordingly:
  • From the menu tree select Communication channels >> Box-to-Box and in the configuration window as part of the Box-to-Box master connection.
  • Under Slave Password enter the password of the Web-IO which you are using as the Box-to-Box slave. In addition, the Slave IP and the local port set in the slave must be entered.
  • Now enable the desired outputs for switching and confirm with Apply.
  • The Box-to-Box master is now ready to use.

Configuration of the Box-2-Box Slave

  • Just as with the Box-to-Box master, you must first log in with Administrator rights.
  • The B2B slave takes on the role of the TCP server and must be configured accordingly.
  • After entering the local port number and the outputs needed for switching, the Box-to-Box connection is fully configured and the two Web-IOs should connect to each other over the network.
  • No PC is now required for further use.

Also interesting: With Box-to-Box 2 an additional box-to-box connection can be configured to create a kind of Y-structure.

Get Started - Order A Trial Version For 30 Days.

Try our products from Wiesemann & Theis free of charge for 30 days by writing in the note of the order: Want to test the product.
If you do not wish to make use of your right of return within 30 days, simply pay the accompanying invoice. Free shipping in Denmark.

#57150 Ready for Box to Box

#57737 Ready for Box to Box

#57151 Ready for Box to Box

#57738 Ready for Box to Box

#57730 Ready for Box to Box