Serial PCI base board, 1kV isolated
WLAN-Thermometer 1x Pt100
1.335,00 kr. (ex. VAT)
PCI Express Motherboard, 1kV isolated
1.485,00 kr. (ex. VAT)
Serial PCI base board, 1kV isolated
WT13021
Serial motherboard for adding
W&T interface modules, 1kV isolation.
1.410,00 kr. (ex. VAT)
Categories: Serial Standard PCI Cards, Serial PC cards
Tag: PC CARDS
Ask a question about this product
Description
Two additional serial ports for stationary PCs
The PCI base board 13021, in combination with W&T interface modules, expands your PC with two isolated serial interfaces. The respective interface type can be freely selected by using the appropriate interface module. This makes it possible to equip the PC with different interfaces without having to use multiple cards.Interfaces:
- 2x serial TTL interface with galvanic isolation
- 1x 32 bit PCI bus
- for 3.3V & 5V PCI systems
- Galvanic isolation between PC, port 1 and port 2
- Isolation voltage 1kV
Management & Connectivity:
- 20mA, RS232, RS422, RS485, Profibus can be mixed on one card
- 2-fold UART PI7C8952 with 128 byte FIFO
- Plug and Play: automatic configuration of base address and interrupt
Standards & Co.:
- Compliant with standards in both office and industrial environments:
- high immunity to interference in accordance with EN 61000-6-2
- Low interference emission according to EN EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
- 5 year guarantee
Technical data:
| System bus: | 32 Bit PCI bus / 33MHz / Universal Voltage | |
| Serial port: | 2x galvanically isolated slots for interface modules | |
| Operating modes: | Different interface types possible | |
| Maximum baud rate: | 460,800 bauds | |
| Data format: | Any | |
| Signals: | RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI | |
| Handshake: | No, RTS/CTS, Xon/Xoff | |
| UART: | PI7C8952 with 128 byte FIFO | |
| Signal lines: | RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI | |
| Galvanic isolation: | Insulation voltage min. 1kV DC between PC and serial ports 1 and 2 | |
| Galvanic isolation: | Isolation voltage min. 1 KV DC between PC and serial ports 1 and 2 | |
| Supply voltage: | 3.3V DC, 5V DC, 12V DC | |
| Current consumption: | typ. 200mA @3.3V typ. 200mA @5V typ. 100mA @12V | |
| Permissible relative humidity: | 0..95% RH (non-condensing) | |
| Housing and other data | ||
| Dimensions: | 134 x 120mm (W x H) | |
| Protection class: | IP00 | |
| Weight: | approx. 105 g | |
| Ambient temperature: | Storage: -40..+70°C Operation: 0..+70°C | |
| Permissible humidity: | 5..95% relative humidity, non-condensing | |
| Scope of delivery: | Serial PCI base board Slot plate quick start Guide |
240425: Successor model for WT13011
In many cases there is a need to equip the ports of a serial interface card with different interface types. For example, it may be necessary to use COM1 as a 20mA programming interface for a PLC because the software used only supports this port, while an RS232 terminal device should be connected to COM2.
For such problems, W&T offers an elegant solution that does not require the use of additional external hardware: The module concept of the serial W&T PC cards allows a completely free choice of interface type by equipping the PC card base board with plug-in modules, which convert the internal TTL signals into the required interface signals.
The combined interface cards are assembled in our company according to your wishes and delivered ready for installation. Replacing the built-in interface is also possible later without any problems by replacing the interface module and can be done by yourself with little effort.
| Product Title: | Product SKU | Add to Cart |
|---|