Com-Server 3x Isolated
Com-Server 3x Isolated
WT58662
3x RS232/RS422/RS485 galvanically isolated, 10/100BT, 24V
4.635,00 kr. (ex. VAT)
Background information:
The Com-Server 3x Isolated is the universal, function-expanded new member of the Com-Server family and successor of the Com-Server Highspeed Isolated 58633 addition to the proven standard operating modes and functions it offers through its high processing speed and new packaging options significantly improved support for working with serial protocols. In addition, there is the possibility serial receive data more participants in the network to provide.Product Features:
- Industrial quality, universal network integration of up to three RS232 / 422/485 devices
- Supply voltage 12-48VDC
- - Please order external power supply as a separate accessory
- Fast startup with EasyStart!
- Remotely configurable via Web Based Management, Telnet, SNMP or Controlsocket
- RS232, RS422m, RS485 are selected for each port
- Serial bit rate up to 230.4 kbit/s
- 10 / 100BaseT autonegotiation
- ++ Wake-on-LAN
- ... Com-Server starts the computer as needed
- Transparent communication per ...
- ... Windows COM Port Redirector
- ... Box-to-Box
- ... TCP server socket
- ... OPC server
- Extended protocol support
- FTP client and server
- Telnet client and server
- UDP Peer
- LET GO
- Meets standards in both office and industrial environments:
- Increased noise immunity for industrial areas
- Stricter noise emission for residential and commercial areas
- 5 year warranty
Technical Data
Connections and displays:
- Serial port:
- 3x RS232/422/485 interface, selectable
- DB9 connector plug
- 50 to 230.400 baud
- 7,8 data bits
- 1,2 stop bits
- Parity No, Even, Odd
- Flow control No, RTS/CTS, Xon/Xoff
- Serial modes:
- RS232
- RS422 4-wire bus master
- RS485 4-wire bus master
- RS485 4 wire with automatic control
- RS485 2 wire with automatic control
- Network:
- 10/100BaseT Autosensing/Auto-MDIX
- RJ45
- IPv6 on request
- Galvanic isolation:
- Network connection: MIN. 1500 V
- Serial ports: 1 kV mutually and with respect to the supply
- Supply voltage:
- Power-over-Ethernet (PoE) or
- DC 12V .. 48V (+/-10%) or AC 9Veff .. 24Veff (+/-10%)
- Supply connection:
- Plug-in screw terminal, 5.08mm spacing
- Labeled "L+" and "M"
- Current consumption:
- PoE Class 1 (0.44 - 3.84W)
- typ. 110mA @24V DC when externally powered
- Displays:
- 1 LED Power
- 3 LEDs Status
- 3 LEDs Error
- 2 LEDs Network Status
Housing and other data:
- Housing:
- Plastic compact housing for top-hat rail mount
- 105x45x75mm (l x w x h)
- Enclosure rating:
- IP20
- Weight:
- approx. 180 g
- Ambient temperature:
- Storage: -40..+70°C
- Operating 0..+60°C (70°C on request)
- Permissible relative humidity:
- 5..95% RH, non-condensing
- Scope of delivery:
- 1x Com-Server 3x Isolated
- 1x Quick Guide
Windows COM Port Redirector
Install the COM Port Redirector and configure your serial program on one of the virtual COM ports - done! Regardless of whether as a replacement for missing hardware COM ports, a solution for virtual environments such as VMware, HyperV, etc. or as a simple line driver, your serial communication becomes network capable without a single line of programming and, if desired, TLS-PSK encrypted. Multipoint mode and packeting options are of course also available. Data sheet with download link
Box-to-Box
In just a few clicks you can link 2 Com-Servers to each other logically and use an operating-system neutral, transparent and if desired TLS encrypted data tunnel through the network. Serial data are sent bi-directional and as fast as possible to the respective counterpart. Automatic reconnect functions in case of connection faults/dropouts are available as are multipoint operation and packeting options for fine tuning when using serial protocols. To application example ...
TCP/UDP socket communication
Network programming is today part of the standard repertoire of all programmers. Integrate your serial device easily into your own network application. Take connection control into your own hands as a TCP client, be contacted event-driven as a TCP server (optional with TLS-PSK encryption) or use the efficient, connectionless UDP protocol. Of course new multipoint operation and packeting options are also available here. To application example ...
NEW! Modbus/TCP-Gateway
Many devices such as energy meters, measuring transducers, frequency converters etc. have an RS232/422/485 interface and communicate via the Modbus/RTU protocol. The Com-Server integrates these devices quickly and reliably in Modbus/TCP environments.
FTP client/server
Send and archive your serial data with the FTP standard tools on most operating systems. Serial outputs from scales, barcode readers etc. or status and error messages for example from UPSs are classic applications for the use of Com-Servers as FTP server or FTP client. To application example ...
Multipoint mode
Distribute the send data from your serial device to as many as six network stations at a time. Regardless of whether you want to archive or monitor, copies of the serial data can be retrieved on a configurable slave port. Filters for the authorized IP addresses are provided to protect against unauthorized access.
Packeting options
Received serial protocols are often sensitive to pauses in the serial data flow. In order to avoid such timeouts and ensure complete transmission of the datagrams in a network packet, the Com-Server 3x Isolated offers numerous configuration options for detecting datagram limits (start/end characters, start + length, etc.).
Software |
||
| WuTility | WuTility | |
| Windows COM Port Redirector Legacy | Download | |
| Windows COM Port Redirector Win 95/98/Me | Download | |
| OPC Server | Software | |