Description
Product properties:
- Tiny plug-in interfaces
- Complete selection of interfaces
- RS232
- RS485/RS422
- RS232/RS422/RS485 (selectable interface type)
- Profibus
- 20mA
Background information:
Due to their modular design, all W&T Com-Servers and most W&T PC cards can be equipped with various port types. In contrast to standard devices that are equipped only with RS232 ports, the interfaces of W&T equipment can be modified by simply replacing the existing interface modules with the desired ones.
Data
TTL plug adapter: |
|
2-mm adapter |
Dimensions: |
|
45x32x14 mm |
Weight: |
|
approx. 15 g |
|
|
|
|
|
RS232/RS422/RS485 combination module, #18813 |
Operating modes: |
|
RS232 RS422 RS485 2/4 wire with handshake control RS485 2/4 wire with automatic control |
Switching time: |
|
approx. 10µs for switching from data send to receive for RS485 automatic control (can be changed on request) |
Transfer rate: |
|
RS232: max. 230 kbaud RS422/RS485: max. 10 Mbaud |
Signals: |
|
RS232: RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI RS422: RxD,TxD,CTS,DTR RS485: RxD, TxD |
Termination: |
|
Connectable termination network |
Power supply: |
|
5 V @20mA |
Output: |
|
9-pin SUB-D adapter |
|
|
|
|
|
RS232 DTE module, #18811 |
Transfer rate: |
|
max. 115,200 baud |
Signals: |
|
RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI |
Power supply: |
|
5 V @20mA |
Input: |
|
2-mm adapter |
Output: |
|
9-pin SUB-D plug |
|
|
|
|
|
RS422/485 module, #18611 |
Operating modes: |
|
RS422 RS485 2/4 wire with handshake control RS485 2/4 wire with automatic control |
Switching time: |
|
approx. 10µs for switching from data send to receive for RS485 automatic control (can be changed on request) |
Transfer rate: |
|
max. 10 Mbaud |
Signals: |
|
RxD,TxD,CTS,DTR |
Termination: |
|
Connectable termination network |
Power supply: |
|
5 V @20mA |
Output: |
|
9-pin SUB-D adapter |
|
|
|
|
|
Profibus module, #18612 |
Operating mode: |
|
RS485 2-wire mode with echo suppression and automatic control of the RS485 transceivers |
Switching time: |
|
approx. 1µs for switching from data send to receive (can be changed on request) |
Transfer rate: |
|
max. 10 Mbaud |
Signal lines: |
|
Bus A/B Vcc and GND for supply of the external termination network |
Power supply: |
|
5 V @40mA |
Output: |
|
9-pin SUB-D socket |
|
|
|
|
|
20mA module, #18411 |
Transfer rate: |
|
max. 19.200 kBaud |
Signals: |
|
RxD,TxD |
Operating modes: |
|
active/passive mode |
Power supply: |
|
5 V @10mA / 12V @40mA |
Output: |
|
9-pin SUB-D plug |
|
|
|
|
|
20mA module, #18412 |
Transfer rate: |
|
max. 19.200 kBaud |
Signals: |
|
RxD,TxD |
Operating modes: |
|
active/passive mode |
Power supply: |
|
3.3...5 volts, max. 210mA at 3.3 V Integrated step-up converter for active mode |
Output: |
|