Com-Server Highspeed 100BaseFX

Com-Server Highspeed 100BaseFX

2,985.00DKK
Direct connection to the network: 1 serial highspeed port to the optical network

Description

Background information:
Especially when bridging long distances up to 2000m, such as found in distantly located facilities or even in cross-building connections, the use of glass fiber optic cables is the ideal transmission medium. Network side galvanic isolation to almost any desired level, with no susceptibility to electromagnetic noise compared with copper based solutions. Likewise, fiber optic cables emit no noise of their own.

Like the other Highspeed series models, the Com-Server Highspeed 100BaseFX offers everything you need for direct connection of a serial port to the computer network in the smallest possible space. All protocols are included (see box and applications behind the product data sheets). The serial port on the Com-Server can be switched to RS232, RS422 or RS485. The serial and network parameters are configured using Telnet, ARP/RARP, SNMP or via the Internet browser and the integrated Web Based Management function.

COM Port Redirector
Purely serial programs can be made to communicate over the network using the included COM Port Redirector for Windows 9x/NT/2000/XP/2003/Vista. Virtual COM ports are installed on the system which look to the applications like standard COM ports. Communication with the terminal device is now however accomplished using the network and a Com-Server (data sheet with download link).

Features

Product properties:

  • Direct connection with compact box for DIN rail mount
  • Noise-immune network connection up to 2000 meters
  • Network side galvanic isolation to almost any desired level
  • Remotely configurable via Web Based Management
  • RS232, RS422, RS485 selectable
    • Optional 20mA/TTY
    • Custom-built modules on request
  • Serial transmission speed up to 115 and 230.4 kbps
  • Network connection:
    • 100BaseFX, ST connector
  • Power supply:
    • 12-24 volts AC/DC
  • Conforms to standards both in office and industrial environments:
    • Increased noise immunity for industrial areas
    • Stricter noise emission for residential and commercial areas

Protocols:

  • Serial port protocols:
    • XON/XOFF
    • Hardware handshake
    • SLIP
    • other protocols on request
  • Protocols for direct network connection:
    • TCP/IP:
      Socket, FTP, Telnet per client and server
    • Auxiliary protocols:
      ARP, RARP, DHCP/BOOTP,PING, RIP, SNMP
      Inventory keeping, group management
  • Protocols for paired Com-Server operation:
    (Connect serial devices in pairs via network)
    • Box-to-box mode TCP/IP

Data

Serial port:    1 x RTS232-, RS422-, RS485 interface
DB9 connector, configurable
Optional 20mA/TTY
Baud rate:   50 to 230.400 baud
Data format:   7,8 data bits, 1,2 stop bits
No, Even, Odd parity
Flow control:   Hardware handshake, XON-XOFF protocol
or can be suppressed
Network:  

100BaseFX for ST connector (SC on request)
Max. distance 2000m

Fiber optic medium:   Duplex Multimode glass fiber 50/125µm or 62.5/125µm, 1300nm
Optical budget:   50/125µm max. 7dB
62.5/125µm max. 10dB
Supply voltage:   DC 12V .. 48V (+/-10%)
AC 18Veff .. 30Veff (+/-10%)
Current consumption:   typ. 110mA @24V DC
Ambient temperature:   Storage: -40..+70°C
When not stacked: 0..+55°C
(+70°C on request)
 
Housing:   Plastic compact housing for DIN rail mount, 105x75x45mm
Weight:   approx. 150g
Delivery:   1x Com-Server Highspeed 100BaseFX
1x product CD with
WuTility management tool, Windows COM Port Redirector, OPC server,
programming examples in C/VB/Delphi/Java, reference manual in German/English

Manual

Firmware

FAQs

Send messages - when limits are violated or timer-based - for informational purposes directly to the responsible technical as an e-mail or as a reroute via SMS.

 

e-5wwww-29-grde-000

After the device has been configured for and connected to your network, the following steps are still necessary.

e-57606-28-piww-000
Open the profile for configuring e-mail alarm messages. e-57606-35-pide-000
Enter the desired parameters. e-57606-36-pide-000
When the limit you have set is exceeded, the device sends an e-mail which can also be transmitted as an SMS message using special functions available from cellular phone service providers. e-57606-37-piww-000

Tools