{"id":187634,"date":"2022-04-26T10:47:57","date_gmt":"2022-04-26T10:47:57","guid":{"rendered":"https:\/\/www.actcom.dk\/modbus-tcp\/"},"modified":"2022-04-26T10:47:57","modified_gmt":"2022-04-26T10:47:57","slug":"modbus-tcp","status":"publish","type":"post","link":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/","title":{"rendered":"Modbus TCP"},"content":{"rendered":"<section class=\"c-intro c-cols\">\n<div class=\"c-heading\">\n<div>\n<p class=\"c-justify\">Modbus-protokollens klare og enkle struktur har f\u00f8rt til, at andre producenter ogs\u00e5 har integreret Modbus i deres enheder.\u00a0Modbus har s\u00e5ledes udviklet sig til en standard, der stadig er etableret i dag.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<hr \/>\n<section class=\"c-category\">\n<h3><b>Herre\/slave princippet<\/b><\/h3>\n<p class=\"c-justify\">Modbus arbejder efter master\/slave princippet.\u00a0Det betyder, at der er mindst \u00e9n master og mindst \u00e9n slave.<\/p>\n<p class=\"c-justify\">Modbus-slaver er f.eks.\u00a0B. PLC-styringer, Web-IO&#8217;er eller andre decentrale IO-moduler til digitale og analoge signaler.<\/p>\n<p class=\"c-justify\">Masteren er altid den kommunikationspartner, der tager initiativet, dvs. sender en foresp\u00f8rgsel eller det \u00f8nskede funktionskald til en slave.\u00a0Hver slave har en unik adresse.\u00a0Normalt er slaven rent passiv og reagerer kun, n\u00e5r den er specifikt adresseret med sin adresse.<\/p>\n<div class=\"c-center\">\n<\/div>\n<div class=\"c-center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/images\/Information\/e-57www-11-pide-000.png\" width=\"600\" \/><\/div>\n<h4><b>Master\/Slave &#8211; Klient\/Server<\/b><\/h4>\n<p class=\"c-justify\">Med den stigende betydning af TCP\/IP Ethernet som transmissionsmulighed blev Modbus-protokollen tilpasset n\u00e6sten 1:1 fra seriel datatransmission til TCP.<\/p>\n<p class=\"c-justify\">Modbus TCP arbejder efter klient\/server-princippet, hvor masteren p\u00e5tager sig rollen som klient, og slaverne fungerer som servere.\u00a0Modbus-masteren skal derfor oprette en eksplicit TCP-forbindelse til hver Modbus-slave.\u00a0Denne forbindelse forbliver p\u00e5 plads, s\u00e5 l\u00e6nge kommunikationen varer.\u00a0Der oprettes ikke en ny forbindelse for hver anmodning.<\/p>\n<p class=\"c-justify\">Den standardiserede TCP-serverport til Modbus TCP er 502.<\/p>\n<h4><b>registre og variabler<\/b><\/h4>\n<p class=\"c-justify\">Hukommelsesadresser eller registre af Modbus-masteren, dvs. klienten.<\/p>\n<p class=\"c-justify\">Man kan forestille sig det, som om Modbus-slaven, alts\u00e5 serveren, havde et skab med et stort antal skuffer, som alle er nummererede.\u00a0Funktioner er tildelt skufferne.<\/p>\n<p class=\"c-justify\">Hvis Modbus-masteren \u00f8nsker at kalde visse oplysninger frem, indtaster den nummeret p\u00e5 det tilsvarende rum i sin anmodning og f\u00e5r indholdet tilbage fra Modbus-slaven.<\/p>\n<p class=\"c-justify\">Hvis Modbus-masteren vil udl\u00f8se noget p\u00e5 slaven, f.eks.\u00a0B. betjener en koblingsudgang, l\u00e6gger han den n\u00f8dvendige information i rummet med det tilsvarende nummer.<\/p>\n<p class=\"c-justify\">Som beskrevet i starten sker dette faktisk via tilsvarende hukommelsesadresser (registeradresser).\u00a0Der er maksimalt 65536 adresser tilg\u00e6ngelige.\u00a0Hvilken funktion er defineret bag hvilken &#8211; er derfor ikke specificeret ensartet.<\/p>\n<p class=\"c-justify\">Som regel er hukommelsen opdelt i omr\u00e5der efter funktioner.<\/p>\n<table>\n<thead>\n<tr>\n<th>betegnelse<\/th>\n<th>datatype<\/th>\n<th>adgang<\/th>\n<th>beskrivelse<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>diskret<\/td>\n<td>1 bit<\/td>\n<td>bare l\u00e6s<\/td>\n<td>digital indgang eller skiftetilstand<\/td>\n<\/tr>\n<tr>\n<td>spole<\/td>\n<td>1 bit<\/td>\n<td>L\u00e6se skrive<\/td>\n<td>digital udgang eller skiftetilstand<\/td>\n<\/tr>\n<tr>\n<td>input registre<\/td>\n<td>16-bit<\/td>\n<td>bare l\u00e6s<\/td>\n<td>V\u00e6rdi mellem 0 og 65535 eller analog v\u00e6rdi eller t\u00e6llerv\u00e6rdi<\/td>\n<\/tr>\n<tr>\n<td>holde register<\/td>\n<td>16-bit<\/td>\n<td>L\u00e6se skrive<\/td>\n<td>V\u00e6rdi mellem 0 og 65535 eller analog v\u00e6rdi eller t\u00e6llerv\u00e6rdi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><b>Funktionskode<\/b><\/h4>\n<p class=\"c-justify\">Inden for Modbus-protokollen angiver funktionskoder, hvilken datatype der skal tilg\u00e5s og hvordan.\u00a0Her er en liste over de mest almindelige funktionskoder:<\/p>\n<table>\n<thead>\n<tr>\n<th>FC (dec.)<\/th>\n<th>FC (hex.)<\/th>\n<th>beskrivelse<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>01<\/td>\n<td>0x01<\/td>\n<td>\n<p>Afl\u00e6sningsspoler<br \/>Afl\u00e6sning af digitale udgange eller koblingsudgange<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>02<\/td>\n<td>0x02<\/td>\n<td>\n<p>L\u00e6s diskrete indgange<br \/>L\u00e6s digitale indgange eller koblingsadgange<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>03<\/td>\n<td>0x03<\/td>\n<td>\n<p>L\u00e6s holdregistre<br \/>L\u00e6sning af 16-bit (output) registre<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>04<\/td>\n<td>0x04<\/td>\n<td>\n<p>L\u00e6s<br \/>inputregistre L\u00e6sning af 16-bit (input) registre<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>05<\/td>\n<td>0x05<\/td>\n<td>\n<p>Skriv enkelt spole<br \/>Skriver en enkelt udgang eller skiftende udgang<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>06<\/td>\n<td>0x06<\/td>\n<td>\n<p>Skriv enkelt register<br \/>Skriv et enkelt 16-bit register<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>0x0F<\/td>\n<td>\n<p>Skriv flere spoler<br \/>Skrivning af flere udgange eller skift af udgange<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>0x10<\/td>\n<td>\n<p>Skriv flere registre Skriv flere<br \/>16-bit (output) registre<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>07<\/td>\n<td>0x07<\/td>\n<td>\n<p>L\u00e6s undtagelsesstatus\u00a0Anmodningsfejlstatus<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<hr \/>\n<section class=\"c-category\">\n<h3>Modbus protokol struktur<\/h3>\n<p class=\"c-justify\">Modbus TCP-protokolrammen har f\u00f8lgende struktur:<\/p>\n<div class=\"c-center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/images\/Information\/e-57www-14-piww-000.png\" width=\"600\" \/><\/div>\n<p><\/p>\n<p class=\"c-justify\"><b>Transaktions-id<\/b><br \/>Transaktions-id&#8217;et er noget som et anmodningsnummer og \u00f8ges med et af masteren for hver anmodning.\u00a0Klienten svarer med det samme transaktions-id.<\/p>\n<p class=\"c-justify\"><b>Protokol ID<\/b><br \/>Altid 0 med Modbus TCP.<\/p>\n<p class=\"c-justify\"><b>L\u00e6ngde<\/b><br \/>L\u00e6ngde af Modbus-data i bytes plus to.<\/p>\n<p class=\"c-justify\"><b>Enheds-ID<\/b><br \/>Med den serielle Modbus-protokol var dette adressen p\u00e5 slaven.\u00a0Feltet er blevet vedtaget af hensyn til kompatibilitet.\u00a0Med Modbus-TCP sker den unikke adressering dog via slavens IP-adresse.<\/p>\n<p class=\"c-justify\"><b>Funktionskode<\/b><br \/>Modbus-protokollen bruger nummererede funktionskoder til at definere, hvad anmodningen sendt af masteren skal udl\u00f8se p\u00e5 slaven.<\/p>\n<p class=\"c-justify\"><b>Modbus Data<\/b><br \/>Modbus dataomr\u00e5det er fyldt med forskelligt indhold afh\u00e6ngigt af den anvendte funktionskode og kan derfor variere i st\u00f8rrelse.\u00a0Dataretningen spiller ogs\u00e5 en rolle i strukturen af \u200b\u200bModbus-dataomr\u00e5det.<\/p>\n<p class=\"c-justify\">Med dataretningen master til slave indeholder de f\u00f8rste to bytes altid den hukommelsesadresse, der skal adresseres.<\/p>\n<div class=\"c-center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/images\/Information\/e-57www-15-piww-000.png\" width=\"600\" \/><\/div>\n<p class=\"c-justify\">F\u00f8lgende eksempel viser, hvordan en Modbus-TCP-pakke ser ud, n\u00e5r to registre med funktionskode 3 hentes fra hukommelsesadressen 0x1020.<\/p>\n<div class=\"c-center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/images\/Information\/e-57www-16-piww-000.png\" width=\"600\" \/><\/div>\n<p class=\"c-justify\">Svarpakken er struktureret anderledes.\u00a0Antallet af overf\u00f8rte registerbytes er indkodet i den f\u00f8rste byte af Modbus-data.\u00a0Indholdet af de \u00f8nskede registre er i de n\u00e6ste 4 bytes.<\/p>\n<div class=\"c-center\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/images\/Information\/e-57www-17-piww-000.png\" width=\"600\" \/><\/div>\n<p class=\"c-justify\">P\u00e5 trods af den klare protokolstruktur tilbyder Modbus TCP stor fleksibilitet til industriel kommunikation.<\/p>\n<p class=\"c-justify\"><b>Tip:\u00a0<\/b><i>V\u00e6r opm\u00e6rksom p\u00e5, om enhedsproducenten angiver v\u00e6rdierne i decimal eller hexadecimal, n\u00e5r du beskriver hukommelsesadresserne<\/i>\u00a0.<\/p>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<h2>Standardprotokol for automatiseringsteknologi<\/h2>\n<p>Modbus blev oprindeligt udviklet som en seriel feltbus af Modicon (i dag Schneider Electric) som en kommunikationsvej mellem deres kontroller.<\/p>\n","protected":false},"author":7,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[544],"tags":[545],"class_list":["post-187634","post","type-post","status-publish","format-standard","hentry","category-teknisk-informationer","tag-modbus-tcp"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Modbus TCP - actcom<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.actcom.dk\/da\/modbus-tcp\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modbus TCP\" \/>\n<meta property=\"og:description\" content=\"Standardprotokol for automatiseringsteknologi Modbus blev oprindeligt udviklet som en seriel feltbus af Modicon (i dag Schneider Electric) som en kommunikationsvej mellem deres kontroller.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.actcom.dk\/da\/modbus-tcp\/\" \/>\n<meta property=\"og:site_name\" content=\"actcom\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-26T10:47:57+00:00\" \/>\n<meta name=\"author\" content=\"Jens Brogaard\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Skrevet af\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jens Brogaard\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/\"},\"author\":{\"name\":\"Jens Brogaard\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#\\\/schema\\\/person\\\/02450ece20a4f695e21026eb1c19e51e\"},\"headline\":\"Modbus TCP\",\"datePublished\":\"2022-04-26T10:47:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/\"},\"wordCount\":717,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#organization\"},\"keywords\":[\"modbus TCP\"],\"articleSection\":[\"Teknisk informationer\"],\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/\",\"url\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/\",\"name\":\"Modbus TCP - actcom\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#website\"},\"datePublished\":\"2022-04-26T10:47:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/modbus-tcp\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Modbus TCP\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#website\",\"url\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/\",\"name\":\"actcom\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#organization\",\"name\":\"actcom\",\"url\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.actcom.dk\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/atcomlogo.png\",\"contentUrl\":\"https:\\\/\\\/www.actcom.dk\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/atcomlogo.png\",\"width\":215,\"height\":68,\"caption\":\"actcom\"},\"image\":{\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/#\\\/schema\\\/person\\\/02450ece20a4f695e21026eb1c19e51e\",\"name\":\"Jens Brogaard\",\"url\":\"https:\\\/\\\/www.actcom.dk\\\/da\\\/author\\\/jensb\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Modbus TCP - actcom","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/","og_locale":"da_DK","og_type":"article","og_title":"Modbus TCP","og_description":"Standardprotokol for automatiseringsteknologi Modbus blev oprindeligt udviklet som en seriel feltbus af Modicon (i dag Schneider Electric) som en kommunikationsvej mellem deres kontroller.","og_url":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/","og_site_name":"actcom","article_published_time":"2022-04-26T10:47:57+00:00","author":"Jens Brogaard","twitter_card":"summary_large_image","twitter_misc":{"Skrevet af":"Jens Brogaard","Estimeret l\u00e6setid":"4 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/#article","isPartOf":{"@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/"},"author":{"name":"Jens Brogaard","@id":"https:\/\/www.actcom.dk\/da\/#\/schema\/person\/02450ece20a4f695e21026eb1c19e51e"},"headline":"Modbus TCP","datePublished":"2022-04-26T10:47:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/"},"wordCount":717,"commentCount":0,"publisher":{"@id":"https:\/\/www.actcom.dk\/da\/#organization"},"keywords":["modbus TCP"],"articleSection":["Teknisk informationer"],"inLanguage":"da-DK","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.actcom.dk\/da\/modbus-tcp\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/","url":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/","name":"Modbus TCP - actcom","isPartOf":{"@id":"https:\/\/www.actcom.dk\/da\/#website"},"datePublished":"2022-04-26T10:47:57+00:00","breadcrumb":{"@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.actcom.dk\/da\/modbus-tcp\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.actcom.dk\/da\/modbus-tcp\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.actcom.dk\/da\/"},{"@type":"ListItem","position":2,"name":"Modbus TCP"}]},{"@type":"WebSite","@id":"https:\/\/www.actcom.dk\/da\/#website","url":"https:\/\/www.actcom.dk\/da\/","name":"actcom","description":"","publisher":{"@id":"https:\/\/www.actcom.dk\/da\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.actcom.dk\/da\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.actcom.dk\/da\/#organization","name":"actcom","url":"https:\/\/www.actcom.dk\/da\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.actcom.dk\/da\/#\/schema\/logo\/image\/","url":"https:\/\/www.actcom.dk\/wp-content\/uploads\/2023\/07\/atcomlogo.png","contentUrl":"https:\/\/www.actcom.dk\/wp-content\/uploads\/2023\/07\/atcomlogo.png","width":215,"height":68,"caption":"actcom"},"image":{"@id":"https:\/\/www.actcom.dk\/da\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.actcom.dk\/da\/#\/schema\/person\/02450ece20a4f695e21026eb1c19e51e","name":"Jens Brogaard","url":"https:\/\/www.actcom.dk\/da\/author\/jensb\/"}]}},"_links":{"self":[{"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/posts\/187634","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/comments?post=187634"}],"version-history":[{"count":0,"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/posts\/187634\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/media?parent=187634"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/categories?post=187634"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.actcom.dk\/da\/wp-json\/wp\/v2\/tags?post=187634"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}